Carestream Sign In
Welcome to Carestream.com's communities.
Our customers and partners have access to powerful online communities and tools. Use this overview to discover the best destination for you. Registration and sign-in are required to access these websites.
Vue Cloud Community
Carestream's Vue Cloud Community is your single point of access to the tools you need to diagnose exams, review a patient portfolio or view real-time department performance.
Carestream.com Communities and Tools
Welcome to Carestream.com's communities.
Our customers and partners have access to powerful online communities and tools. Use this overview to discover the best destination for you. Registration and sign-in are required to access these websites.
Vue Cloud Community
Carestream's Vue Cloud Community is your single point of access to the tools you need to diagnose exams, review a patient portfolio or view real-time department performance.
BioMax TranScreen Instructions
Sample Preparation
Generally, a sample that is prepared for autoradiography should be thoroughly dried to minimize attenuation of the beta emission. The procedure of placing a wet blot or sample in plastic wrap or a baggie seriously degrades sensitivity and resolution, particularly when using isotopes of lower energy (e.g., 35 S), and will totally eliminate effective 3 H detection. Further, it is important that any blotting material used in an experiment be that which has the maximum affinity for the blotted biomolecule; e.g., positively-charged nylon for a nucleic acid. Proper choice of the membrane assures that radioactivity is closest to the surface (defining an active side of the blot) which can be placed closest to film and phosphor to maximize sensitivity and spatial resolution.
The assurance that a blot be capable of stripping and re-probing after drying for autoradiography is of some concern. Generally, if the blotted molecules are appropriately cross-linked to the membrane, and the blot is appropriately blocked and probed, stripping and re-probing after drying is not adversely affected.
The simple operational definition of air-dried is sufficient for use with the BioMax TranScreen, whereas the slightest dampness can cause a severe sticking and/or static problems if a blot is exposed to the surface of a film. The BioMax TranScreen surface effectively resists the adverse effect that water and/or ice would ordinarily have on the phosphor.
Darkroom and Safelights
IMPORTANT: BioMax MS film is extremely sensitive to green, yellow, and blue light and should only be exposed to the red GBX-2 safelight filter, 7.5 or 15 watt bulb only. Use of other safelight filters or higher power bulbs will result in significantly increased background fog on the exposed film. Please refer to instructions and precautions provided with the film. The BioMax TranScreen is robust to light exposure over indefinite periods of time. In addition, the time period of light emission after phosphor exposure is sufficiently short (seconds) as to warrant no special precautions involving dark adaptation of the screen.
Instructions for the use of the BioMax TranScreen System
STEP 1.
Under proper darkroom conditions, remove the film from the box and insert it into the BioMax TranScreen folder. The BioMax TranScreen folder is designed to help minimize film fogging due to poor darkroom conditions. Refer to darkroom and safelight section for information on proper darkroom conditions.
STEP 2.
Place the active side of the sample onto the phosphor surface of the folder as shown in the diagram.
STEP 3.
Place the film/screen combination into a cassette and close the cassette.
STEP 4.
The cassette should then be placed into a freezer (-60 to -80C). It is important to use the freezer to maximize the sensitivity of the system.
STEP 5.
After exposure, allow the cassette to warm to room temperature for at least 15 minutes prior to opening. This will help prevent damaging the cassette hinge and minimize water condensation forming on the exposed film, sample and BioMax TranScreen screen.
STEP 6. Under proper darkroom conditions, open the cassette and disassemble the constructed sandwich. The BioMax TranScreen folder is notched in one corner to facilitate easier access to the film.
Choose a Region
- Africa
- Asia Pacific
- Europe
- Middle East
- North America
- South America
Africa
Saint Helena
Sao Tome and Principe Senegal Seychelles Sierra Leone Somalia South Africa Sub Sahara Africa Sudan Swaziland Tanzania Togo Tunisia Uganda |
Western Sahara
Zambia Zimbabwe |
Asia Pacific
Europe
Serbia
Slovakia Slovenia Spain Sweden Switzerland Ukraine United Kingdom |
Middle East
North America
South America
São Vicente and Granadina
Suriname Trinidad and Tobago Turk and Caicos Islands Uruguay U.S. Virgin Islands Venezuela Virgin Islands (British) |